Are Tippmann Paintball Guns easy to maintain? [98, A5, Crossover, Gryphon, TiPX, X7, Phenom, Alpha Black, Carver One, Project Salvo]


Paintball guns are basically pneumatic tools.  Keeping them clean and lubricated are the most important things. Replacing the internals seals at least 1 time per year (2-3 times if you are a more

E-Grip Trigger Board Problem [98, A5, Crossover, X7, Phenom, Alpha Black, Carver One, Project Salvo]


If you have a problem with an E-Grip Trigger, these steps may help to solve your issue: Before doing and trouble shooting of any kind, make sure your marker is degassed and follow your manual for di

Tippmann Stock A5 and X7 Valve Updates


The Tippmann A5's and X7's (not the Phenoms ) use almost the identical internal valve. In fact, when the X7 first came out it used the same valve as the A5. The original valve assembly used in A-5's

Installing a Shoulder Stock - Tippmann and US Army [98, A5, X7, Phenom, Alpha Black, Carver One, Project Salvo]


To assemble a stock on a 98 series gun , please follow the disassembly procedures in your gun manual . You will need to remove the End Cap and insert the stock into the slots where the End Cap was. Yo

Feed elbow, cyclone feed, or front sight attachment problems [98, Alpha Black, Project Salvo]


On the 98 Custom series , Alpha Blacks , and Project Salvos , the feed elbow or cyclone feed housing attaches to the body with 2 pins on the bottom, and then locks into place by latching on the front

Cyclone Feed Troubleshooting [98, A5, X7, Phenom, Alpha Black, Project Salvo]


Cyclone troubles?  Try these helpful tips Always keep the cyclone clean.  Broken paint and shell will get on the Feeder Housing , Sprocket Paddles , Feeder Axle ,

Response Trigger Troubleshooting [98, A5, X7, Alpha Black Elite, Project Salvo]


Response Trigger isn't getting a burst rate of fire To Tune the RT System Follow the air cylinder installation and velocity screw adjustment instructions in the Getting

Air Volume Valve Spacer [Crossover]


For play requiring lower velocity settings, it may be necessary to utilize the Air Volume Spacer included with the Crossover. To install: 1) Follow Unloading Your Marker on page 10 and Air/CO2 C

Shooting / Air System / Leak Problem Troubleshooting [X7 Phenom]


To troubleshoot an X7 Phenom air leak, first determine the location of the leak. If the leak is from the Tank /  Tank Adapter ASA : This leak comes from a cut or nicked 18-PA Tank Valve Oring .

Shooting / Air System / Leak Problem Troubleshooting [Crossover]


To troubleshoot a Tippmann Crossover air leak, first determine the location of the leak.   If the leak is from the Tank / ASA Regulator connection: This